NateenCARE ASSISTANT
Absorption · For families and professionals

Measuring absorption: what the numbers really say

A figure in millilitres, fluid ounces or cups does not tell the whole story. Here is how the Rothwell method is measured, why the test liquid changes the result, and the three measures Nateen commits to publishing for every product.

What is the Rothwell method (ISO 11948-1)?

ISO 11948-1 is the only international standard that tests a whole absorbent product. The protocol, known as Rothwell, is simple: the dry product is weighed, immersed in the test liquid for 30 minutes, drained for 5 minutes, then weighed again. The weight difference is the total absorption capacity.

It is a laboratory value obtained under ideal conditions: fully immersed, no pressure, no movement. It is the shared benchmark for comparing manufacturers and remains the most requested criterion in public and hospital tenders.

Water, saline, urine: three liquids, three results

The core of a product is made of cellulose and superabsorbent polymer (SAP). SAP swells by holding water through osmosis. Dissolved ions (sodium, chloride, urea, minerals) reduce that swelling: the more loaded the liquid, the less the polymer retains.

The values announced on our product pages were measured with water following the Rothwell protocol: they are maxima. The ISO standard prescribes 0.9% saline, closer to urine: it gives only about 38% of the value measured with water. Real urine varies further from one person to another and hour to hour, with hydration, diet and medication.

In real use, the profession estimates the useful capacity of a product at about one third of its Rothwell value. That is not a product flaw: it is the difference between an immersion test and a body that moves, sits and presses on the product.

Water, saline, urine: three liquids, three results1 · Rothwell method (ISO 11948-1)2 · The liquid changes the result3 · Three measures that matterDry productImmersed 30 minDrained 5 mingWeighedTotal absorption = wet weight − dry weight100 %≈ 38 %≈ 33 %Waterannounced value0.9% saline≈ 38% of the water valueReal urine≈ 1/3 of the valueNa⁺ Cl⁻Maximum absorbencyhow much (ml · fl oz · cups)ROA · rate of absorbencyhow fast (s)Rewetwhat the skin feels (g · oz)
Water, saline, urine: three liquids, three results

Three measures that matter

Maximum absorbency (Rothwell) answers "how much". It is useful to rank products, provided the measurements were made with the same liquid.

Rate of absorbency, or ROA, answers "how fast". A void arrives in seconds: if the core does not absorb quickly enough, liquid escapes at the sides before it is held. It is the key measure against leaks, at night and for bedridden people.

Rewet answers "what the skin feels". Pressure is applied to an already loaded product and the moisture that returns to the surface is weighed. Low rewet means dry skin, hence fewer irritations and incontinence-associated dermatitis.

Measuring the rate (ROA)1 · Measuring the rate (ROA)2 · Why speed matters3 · What speeds absorption upFixed dose pouredTimer startedNo liquid left on topTimer stoppedROA = volume absorbed ÷ time (ml/s · fl oz/s)A void arrives in a few secondsFast coreliquid is capturedSlow coreleaks at the sidesFast = no leakAt night, lying or seated:speed decides before capacityAcquisition layerspreads liquid alongthe whole lengthCellulose + SAP corecaptures, then gels the liquid1 · 2 · 3Test repeated 3 timesthe 3rd dose, on a loadedcore, matters most
Measuring the rate (ROA)
Measuring rewet1 · Measuring rewet2 · What the skin feels3 · What keeps the skin dryLoaded productWeighed filter paper + weightPressure 1 mingPaper weighed againRewet (g · oz) = paper after − paper beforeThe body presses on the productLow rewetdry skinHigh rewetmoisture, irritationDry = protected skinLess moisture coming back, lessincontinence-associated dermatitisSAP gelslocked liquid does not come backTop sheetlets liquid through tothe core, holds noneWetness indicatorchange when saturated, not before
Measuring rewet

How Nateen calculates and displays absorption

To stop mixing water, saline and marketing figures, we display one number per product, calculated the same way for the whole range from the factory technical data sheet (TDS): theoretical maximum absorbency = (55 × SAP weight in g + 14 × cellulose weight in g) × adjustment coefficient, in millilitres, then converted to fluid ounces and cups. Both cores add up when the product has two.

The coefficient (1.05 today) is set in one place: changing it updates every value on the site at once. Laboratory measurements are generally higher than the calculation; we will publish the reports next to the calculated figure, with the test liquid used.

Why Nateen goes further

Common market practice is to display a single Rothwell value and keep the other results in-house. We believe a professional should see all three measures, with the test liquid used, before choosing.

Common practiceNateen
A single Rothwell value, liquid not statedThree measures per product: maximum absorbency, ROA, rewet, with the test liquid stated
Certificates on request, for tenders onlyLaboratory reports downloadable from every product page (publication in progress)
Water or saline value, no distinctionWater value (announced) and 0.9% saline value side by side
Sizes S to XLSizes XS to 4XL, three complementary families (briefs, pants, underpads)
Change as soon as the product is usedNateen is built to last the day; Hospeen, our line priced right, is changed once used

Choosing well is more than one number

The right product depends on the person: mobility, body shape, type and timing of leaks, skin condition, how often a change is possible. A product too absorbent for the need is uncomfortable and costly; one too weak leaks.

Our rule: as discreet as possible, as absorbent as necessary. The Nateen assistant asks five questions and suggests a product and a size, never a diagnosis.

FAQ

Why does a product not absorb the stated value in use?

The stated value is a total capacity measured by immersion (Rothwell). In use, body pressure, position and the ions in urine reduce retention: expect about one third of the value.

What is ROA?

Rate of absorbency is how fast the core takes in a dose of liquid. The faster it is, the less time liquid has to leak at the sides.

What is rewet?

The amount of moisture that comes back to the surface of a loaded product when pressed. The lower it is, the drier the skin stays.

  1. ISO 11948-1 — Urine-absorbing aids, whole-product testing (Rothwell method)
  2. EDANA / INDA (NWSP) methods for rate of absorbency and rewet
  3. nateen.ae product pages — announced values, measured with water